Service Support Spirit
“Pxx” submenu listing:
Step
PXX. Setting and Initial
Yellow Red
Remark
NO. range length Parameter LED LES
adjust
P00 0-1 1
1
P00 1 Recovering amending parameter interval
Setting manual lift speed of torch, the
P01 0-50 1
50
minimum speed is 0, the maximum
P01 50
speed is 50. CNC_THC_UP also use this
speed.
Setting manual descend speed of
P02 0-50 1
50
torch , the minimum speed is 0, the
P02 50
maximum CNC_THC_DN also use this
speed.
P03 0-50 1
50
Setting auto lift speed, minimum is
P03 50
0,maximum is 50.
P04 0-50 1
50
Setting auto descend speed, minimum is
P04 50
0,maximum is 50.
Unit: Volt(V). The value of protecting arc
P05 10-50 1
30
voltage. It can avoid torch descend
P05 30
rapidly because of arc voltage increase
too big.
Unit: volt(V). The arc voltage precision of
adjusting. For example, setting it as 1V, if
P06 1-10 1
1
P06 1 D-value between setting arc voltage and
practical arc voltage is under 1V, it will not
start auto start.
Sensitivity coefficient can make the
sensitivity coefficient can make the
P07 1-50 1
6
P07 6 sensitivity higher. But if it is too higher,
torch will quiver around the balance
location.
Unique Solution
WWW.ARCBRO.COM
18
    "