Diagnosis: to monitor the IO status of current system
Device parameter: used to set parameters related to device
Laser rated power: used to set the rated power of laser
Maximum deflection angle of galvanometer: used to set the range of the maximum deflection angle
of galvanometer.
Maximum frequency: set the maximum frequency of laser PWM signal. When PWM frequency set
by welding parameter exceeds the maximum frequency, the frequency will be limited to the maximum value.
Maximum swing length: set the maximum length during swing. When the length set by welding
parameter exceeds the maximum length, the length will be limited to the maximum length.
Wire feeding step: used to set the step during motor wire feeding.
Direction of motor wire feeding: used to set the direction polarity of motor wire feeding.
Galvanometer correction coefficient: when there is a nuance in the set length and the actual length, it
can be modified by this parameter. When there is no need for correction, it is usually set as 1.
Lens temperature alarm enable: enable lens temperature alarm. When the temperature exceeds the
limited value, the alarm signal will be generated.
Lens temperature alarm limited value: the limited value of lens temperature
Laser alarm enable: used to enable laser alarm. When laser generates alarm, the alarm signal will be
generated.
Laser alarm level: used to set laser alarm to trigger the level logic.
Water-cooling machine alarm enable: used to enable water cooling machine alarm. When the water
cooling machine generates alarm, the alarm signal will be generated.
Water-cooling machine alarm level: used to set water-cooling machine alarm to trigger the level logic
Low pressure alarm enable:used to enable gas alarm. When gas low pressure generates alarm, the
alarm signal will be generated.
Low pressure level: used to set low pressure alarm to trigger the level logic.