NTTF/H-3000
Intelligent Temperature Controller
USER MANUAL
Please read this manual thoroughly for the instruction of correct usage before using this product and keep this manual
as a reference.
l Before cleaning the controller, please ensure that the power is switch off.
l Please remove stains on the display panel by using a soft cloth only.
l No scrubbing or touching the display panel with any hard object, the display panel can be easily scratched.
l Do not press any button on the display panel using pointy objects such as ballpoint pen or screw driver, it can
easily scratch the panel or damage buttons on the panel.
Please confirm the product you received is in full agreement with the model that you selected according to the
following codes:
① Panel size(mm)
H:48*96 E:72*72
② Model:3
③ Control Mode
0:On-Off Control
4:On–Off PID Control (heating Type)
④ Timing Output
0: no timing output
1: Relay Output
2: Buzzer Output (internal)
3: Buzzer Output (external)
⑤ Timer Mode
0: NO timing
1: Timer Startup by a switch and display counting down
2: High and low temperature control, Timer Startup by a short current
and display counting down
3: Timer Startup with set temperature and Counting down
4: Turn switch on to start timer and the relay will be closed. When the
timer reaches the preset value, the relay will be opened.
5: Release switch to start timing, display will show remaining time,
when the timer research preset value, the relay will be closed.
6: Releasing switch to start timing, the relay will be closed, when the
time reaches the preset value, the relay will be opened.
⑥ Output Type
Omit: Relay Output
V: Logic Output (for the control of solid-state relay SSR)
G: SRC ((under 300W only)
WG: external silicon controlled rectifier
WR: external relay
⑦ Thermocouples types:
K:0-800℃;E:0-600℃;J:0-550℃
⑧ LRL
⑨ URL
2.1 Caution when installing
Please install the controller under the following conditions:
l Temperature: 0 to 50 degrees C.
l Humidity: 45% to 85% RH.
l Atmospheric pressure: 86 to 106kPa
Please avoid the following conditions during installation:
l Rapid temperature changes, leading to dew condensation.
l Corrosive gases (especially sulfide gas, ammonia, etc.) or flammable gases.
l Direct vibration or shock
l Contact with water, oil, chemicals, steam , smoke, or hot water
l High concentrations of atmospheric dust, salt or iron particles
l Large inductive interference, resulting in static electricity, magnetic fields or noise.
l Direct sunlight.
l Radiant heat sources, etc
2.2 Mounting Process
(1)Cut out rectangle holes on the panel for installing the controller according to the required hole size.
NTTF/H-3000
When installing more than one controller, the minimum horizontal and vertical distance between two holes should be
25mm and 30mm respectively.
(2)Insert the controller into the hole on the panel.
(3)Insert mounting bracket in the slot for mounting the controller.
(4)Push the mounting bracket tightly to connect the instrument and the panel firmly.
2.3 Panel layout
①Display (Red)
• Display the measuring temperature
②Display (Green)
• Display the set time
③Indicator
• OUT indicator for heating output (Green), Bright at working.
• SETTEM indicator (Red): Bright when setting the temperature
• AT/ALM indicator (Red), Bright at working.
• SETTIME indicator (GREEN): Bright when setting the time
④Function key
• Used to modify the setting value, calling out, modify and
confirm the parameters。
⑤ , ⑥Digital Adjustment Key
• Used to modify the setting value and the control parameters, or
for entering in the timing state.
2.4 Key Performance
1) Measurement accuracy: 0.5%±1dig 2) Power: 220VAC 3)Operation Temperature:0~50℃ 4)Fuzzy PID control
5) This product conforms with the “Q/SQG01-1999 Intelligent Digital Display Adjustor” Standard Regulation.
3.1 Attention to the wiring
(1) For thermocouple input, the corresponding compensation line should be used.
(2) Input signal lines should be far away from power supply and load lines to avoid noise interference.
3.2 Wiring Terminal’s configuration
2
85~264
VAC
3
OUT1
+
3
4
~
-
4
5
6
9
OUT2
10
11
+
TC
12
-
13
KT
4.1 The order of calling out the various functions
After the instrument is power on, the upper row displays InP and the lower row displays the calibration mark of the
sensor to express the input type. 4 seconds later, the upper row displays the upper limit of the measuring range and the
lower row displays the lower limit of the measuring range then the measurement range is determined. Again after 4
seconds, the upper row displays the measuring value and the lower row displays the setting value. And then the system
enters its normal working state.