SUNFAR Self-Defined Communication Protocol 78
Data classification
(Sent by main
machine)
6
Read operation
3 information of
slave machine
4
Reserve
F
7
Main
machine
control
#
Feature information (Slave machine response )
8
Main
machine
frequency
setting
9
Reserve
10
Reserve
11
Reserve
#
#
#
#
12
Reserve
#
For example: If the data classification value in the frame sent by main machine is 0,
the feedback information of slave machine is 400015,which means that 4 represents
voltage class – 380V; 0 is feature information value; 0015 represents power–1.5kw.
1.3.2 Command classification 1- Read running parameters of slave machine
Main machine sending frame size is 14 bytes, while slave machine response frame
size is 18 types.
0 1 2 3 4 5 6 7 8 9 10 11 12 13
1
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
0
Data subitem: is corresponding to number of monitoring parameter items of the
inverter; as for E550 series inverter, the number of monitoring parameter items is
shown as below:
E550 Series Universal Low-Power Inverter
    "