Functional Details 64
F5.10 Breakage detection lower limiting value Setting range: 0.0 ~50.0%
F5.11 Breakage detection delay time
Setting range: 0.1 ~10.0Sec
If the system’s feedback value is less than the breakage detection lower limiting
value, it is deemed that the system is at the break ge status and the system starts
detecting breakage. After the delay time, if the system is still at the breakage status,
then it is deemed that there is a breakage fault.
6.7 Special machine parameter group
F6.00 Cutting function selection
Setting range: 0000~0001H
This parameter is used to select if this inverter is used for cutter dragging or cutting
control.
0: As the dragging control
1: As the cutting control
F6.01 Cutting length
Setting range:: 0.01~10.00
F6.02 Correction of liner speed coefficient Setting range: 0.01~10.00
This group of parameters is effective for cutting control. The cutting length is the
set value of required wood length in the unit of meter. [F6.02] parameter is used for
length correction which will be done according to mechanical characteristics.
F6.03 Start delay
F6.04 Stop delay
Setting range:: 0.01~10.00
Setting range: 0.01~10.00
This group of parameters defines the cutting start delay and stop delay, which is
related to the length of the first plate and last plate.
F6.05 Reserve
E550 Series Universal Low-Power Inverter
    "