Functional Details 60
F3.31 Swing frequency center frequency setting Setting range: 0.0~[F0.04]
Swing frequency center frequency means the center value of inverter’s output
frequency at the swing frequency runing status.
See Figure 6-17 for detailed process of swing frequency running
Running frequency
Kick frequency [F3.28]
Swing frequency center frequency
Swing frequency amplitude [F3.27]
[F3.29]
Time
[F3.30]
Figure 6-17 Swing Frequency Runing Process
6.5 Communication functional parameter group
F4.00 Communication setting
Setting range: 0000 ~ 0125
This parameter is used to set characteristics relevant with communication (fratile
decimal system setting)
LED Units: Baud rate selection
0: Reserve
1: 1200bps
2: 2400bps
3: 4800bps
4: 9600bps
5: 19200bps
When serial port communication is adopted, the communication parties must have
the same baud rate.
LED Tens: Data format selection
0: No check
1: Even check 2: Odd check
When serial port communication is adopted, the communication parties must have
the same baud rate.
LED Hundreds: Protocol selection
0: RS485 protocol
1: MODBUS communication protocol
LED Kilobit: Reserve
E550 Series Universal Low-Power Inverter