Functional Details 57
4: Continuous cycling mode
The basic running way is the same as the mode 0. The inverter will start cycling
from the first speed after completion of one cycle.
The inverter runs in a cycle of 8 different speeds. That is to say, after completion of
running at the 8th speed, it will start running in a cycle from the first speed.
F3.18 Stage 1 running time
F3.19 Stage 2 running time
F3.20 Stage 3 running time
F3.21 Stage 4 running time
Setting range: 0.0 ~ 6000 Sec
Setting range: 0.0 ~ 6000 Sec
Setting range: 0.0 ~ 6000 Sec
Setting range: 0.0 ~ 6000 Sec
[F3.18][F3.21] Multi-speed frequency 14 running time
Note: the running time at different stage means the time from the end time of
previous stage to the end time of the current stage, including the acceleration
time or deceleration time for running to the current stage frequency.
F3.22 PLC multi-stage running direction Setting range: 0000 ~1111H
Define PLC multi-speed running direction (fratile binary system setting)
PLC running direction setting.
LED UNITS: Stage 1 direction selection
0: FEW
1: REV
LED Tens: Stage 2 direction selection
0: FEW
1: REV
LED Hundreds: Stage 3 direction selection
0: FEW
1: REV
LED Kilobit: Stage 4 direction selection
0: FEW
1: REV
E550 Series Universal Low-Power Inverter
    "