Functional Details 55
Fre频que率ncy
D减ece速lera时tion间tim调e ad整justment
DC voltage
直流电压
[ F 3[F.31.122]]
时Tim间e
时Tim间e
Figure 6-16 Voltage Stall Protection during Deceleration
F3.13 Current amplitude limiting level
Setting range: 150 ~ 250(%)
This parameter specifies maximum current allowed to be output by the inverter,
which is expressed by the percentage of rated current of the inverter. No watter
what working status (acceleration, deceleration and steady running) the inverter is
at, when the inverter’s output current exceeds the value specified by this parameter,
the inverter will adjust the output frequency to control the current within the
specified range to avoid over current tripping.
Inverter’s control software version number is read only.
F3.15 ~F3.16
Reserve
F3.17 Multi-speed running mode
Setting range: 0000~0042H
Setting of basic characteristics of multi-speed running(fratile decimal system settin
setting)
LED UNITS: Simple PLC action selection
0: Simple PLC void
1: Simple PLC effective
E550 Series Universal Low-Power Inverter