Functional Details 53
6.4 Multi-speed and senior running parameter group
F3.00 Multi-speed frequency 1 Setting range: 0.0Hz ~ Upper limiting frequency
F3.01 Multi-speed frequency 2 Setting range: 0.0Hz ~ Upper limiting frequency
F3.02 Multi-speed frequency 3 Setting range: 0.0Hz ~ Upper limiting frequency
F3.03 Multi-speed frequency 4 Setting range: 0.0Hz ~ Upper limiting frequency
F3.04 Multi-speed frequency 5 Setting range: 0.0Hz ~ Upper limiting frequency
F3.05 Multi-speed frequency 6 Setting range: 0.0Hz ~ Upper limiting frequency
F3.06 Multi-speed frequency 7 Setting range: 0.0Hz ~ Upper limiting frequency
It is to set terminals with this parameter function code to control multi-speed
running output frequency.
F3.07 Liner speed coefficient setting
Setting range:0.01 ~ 100.00
This parameter is used to set the running liner speed and display value of liner
speed. It can be also used to display other physical quantity proportional to output
frequency.
Running liner speed (d-8) = F3.07 X Output frequency (d-0)
Set liner speed (d-9) = F3.07 X Set frequency (d-6)
F3.08 Monitoring parameter selection
Setting range: 0 ~ 22
This parameter is used to determine the display contents on the operating panel at
the monitoring status.
The monitoring parameter selection is used to determine the display content on the
LED.
The physical quantity corresponding to the display data can be referred to the status
monitoring parameter table.
E550 Series Universal Low-Power Inverter