Functional Details 40
F1.06
F1.07
AO output lower limit
AO output upper limit
Setting range: 0.0 V ~ [F1.07]
Setting range: [F1.06] ~ 10.0 V
Define the maximum value and minimum value of analog output AO output signal.
Refer to figure 6-7.
AO
[F1.06]
10
Rate
Upper
current
limiting
frequency
Output
frequency
1
Output voltage
2
Max./rate voltage Output current
Figure 6-7 Analog output content of analog output terminal
F1.08
F1.09
Function selection for input terminal 1
Function selection for input terminal 2
Setting range: 0 ~ 29
Setting range: 0 ~ 29
F1.10
F1.11
Function selection for input terminal 3
Function selection for input terminal 4
Setting range: 0 ~ 29
Setting range: 0 ~ 29
Function definition of switch quantity input terminal X1X4, which is described
as below:
0: control terminal in idle
1: Multi-speed control 1
2: Multi-speed control 2
3: Multi-speed control 3
The combination of multi-speed control terminals can be used to select multi-speed
output frequency. The frequency setting at each stage is to be determined by the
multi-speed control parameter functional group ([F3.00][F3.06]).
4: FWD jog control
5: REV jog control
When the external terminal of running command channel selection is effective, this
parameter can define the input terminal of external jog signals.