Functional Details 39
F1.03
F1.04
Minimum set frequency
Maximum set frequency
Setting range: 0.0Hz ~ [F1.04]
Setting range: [F1.03] ~ [F0.04]
The corresponding relationship between the analog input quantity and set
frequency is shown in Figure 6-6.
Frequency
Output frequency
[F1.04 ]
[F1.03 ]
F[1.00]
F[1.00] VVoollttaaggee
[F1.00 ]
[F1.01 ]
Figure 6-6 Corresponding relationship sketch of analog input quantity and set frequency
F1.05 Analog output selection
Setting range: 0 ~ 2
Select the meaning of analog output terminal AO (setting of fratile decimal system).
LED Units: Define meaning of analog output AO
0: output frequency
The analog output (AO) amplitude is proportional to the inverter’s output frequency.
The setting upper limit of analog output ([F1.07]) is corresponding to the upper
limiting frequency.
1: output current
Analog output (AO) amplitude
It is proportional to the inverter’s output current. The setting upper limit ([F1.07])
of the analog output is corresponding to two times of the inverter’s rated current.
2: Output voltage
The analog output (AO) amplitude is proportional to the inverter’s output voltage.
And the setting upper limit ([F1.07]) of the analog output is corresponding to the
maximum output voltage ([F0.13]).
E550 Series Universal Low-Power Inverter