Vo电ltag压e
[F0.13]
Functional Details 36
[F 0 .11 ]
B提oo升st
vo电lta压ge
[F 0.12] Fr频eq率uency
Figure 6-4 Torque Boost Sketch
F0.12 Basic running frequency Setting range: 5. 0Hz ~ upper limiting frequency
F0.13 Maximum output voltage Setting range: 25 ~ 250V/50 ~ 500V
The basic running frequency is the minimum frequency at the maximum voltage of
inverter output. It is generally the motor’s rated frequency.
The maximum output voltage is the output voltage corresponding to the inverter
output basic running frequency, and it is the motor’s rated voltage.
The two items of function parameters need to be set according to motor parameter,
and do not need any modification unless in special cases.
F0.14 Jog acceleration time
Setting range: 0.1 ~600.0Sec
F0.15 Jog deceleration time
Setting range: 0.1 ~600.0Sec
The transit acceleration and deceleration time between initial running frequency
and jog frequency.
F0.16 FWD jog frequency
Setting range: 0.0Hz ~[F0.04]
F0.17 REV jog frequency
Setting range: 0.0Hz~[F0.04]
Jog running is a special running mode of the inverter. Within the effect period of
jog signals, the inverter runs at the frequency set by this parameter.
No matter the inverter is initially stopped or running, it can receive jog signals.
E550 Series Universal Low-Power Inverter