Functional Details 33
3: Special mode for terminal machine:
This function is only applicable to special occasions such as terminal machine. X1
is used as the approach switch counting and stop signal, and X2 is start signal.
LED Hundreds: REV prevention
0: REV prevention void
1: REV prevention effective
LED Kilobit: Power-on auto start
0: Power-on auto start forbidden
1: Power-on auto start allowed
F0.03 Lower limiting frequency
Setting range: 0.0 Hz ~ [F0.
This parameter is the minimum output frequency allowed for the inverter. For the
functioning mode when it is lower than the lower limiting frequency, please refer to
parameter [F0.19].
F0.04 Upper limiting frequency Setting range: [F0.3] ~ 1000.0Hz
F0.05 Acceleration time
F0.06 Acceleration time
Setting range: 0.1 ~ 600.0Sec
Setting range: 0.1 ~ 600.0Sec
It is used to define the velocity of increasing and decreasing of inverter’s output
frequency.
Acceleration time: the time required for output frequency accelerating from
0.0Hz to the upper limiting frequency [F0.04].
Acceleration time: the time required for output frequency decelerating from
upper limiting frequency [F0.04] to 0.0Hz.
E550 Series Universal Low-Power Inverter
    "