Function Parameter Table 24
Parameter Function
Type
Code
Name
Frequency input
F1.28
channel
combination
F1.29
-
F1.31
Reserve
Setting Range and
Description
0: External voltage
+ panel
potentiometer
1: External
voltage+panel
potentiometer +
Digital setting
2:Communication +
external voltage
3: Communication
+ external voltage +
panel potentiometer
4:Communication +
digital-panel
potentiometer
5:Communication -
external voltage
6:Communication +
external voltage -
panel potentiometer
7:External voltage
+ digital - panel
potentiometer
8:Panel
potentiometer -
Digital setting
9:UP/DW+
External voltage
10: UP/DW + panel
potentiometer +
external voltage
Minimum Default
unit setting
1
0
Modification
limit
F2.00 Start frequency 0.0 ~ 50.0Hz
0.1
1.0
F2.01
Start frequency
duration
0.0 ~ 20.0 Sec
0.1
F2.02
Stop mode
0: Deceleration stop
1: Free stop
1
F2.03
Stop DC braking
frequency
0.0~[F0.04]
0.1
F2.04
Stop DC braking
current
0 ~ 100(%)
1
F2.05
Stop DC braking
time
0.0 ~ 20.0 Sec
1
F2.06
Acceleration
torque level
110 ~ 200(%)
1
Motor overload
F2.07 protecting 50 ~ 110(%)
1
coefficient
Dynamic
F2.08
braking
Initial
300 ~ 400V/
600 ~ 800V
1
voltage (1)
0.0 ×
0
3.0
10 ×
0.0
170
110
370
740
F2.09
Reserve
E550 Series Universal Low-Power Inverter