Function Parameter Table 21
Parameter Function
Type
Code
F0.08
F0.09
Name
Carrier
frequency
Modulation
mode
F0.10
Parameter write
and protection
F0.11
F0.12
Torque boost
Basic running
frequency
Setting Range and
Description
1.5 ~ 10.0kHz
0: Asynchronous
1: Synchronous
1: Only allowing to
rewrite F0.01
parameter and this
parameter
2: Only allowing to
rewrite this
parameter
Other values: All
parameters are
0.0 ~ 20.0 (%)
5.0Hz ~ Upper
limiting frequency
Minimum Default
unit setting
0.1
8.0
1
0
1
0
0.1
6.0
0.1
50.0
Modification
limit
×
F0.13
Maximum 25 ~ 250V/
output voltage 50 ~ 500V
1
220/
440
F0.14
Jog acceleration
time
0.1~ 600.0 S
0.1
F0.15
Jog deceleration
time
0.1~ 600.0 S
0.1
F0.16
FWD jog
frequency
0.0Hz~[F0.04]
0.1
F0.17
REV jog
frequency
0.0Hz~[F0.04]
0.1
LED Units:
running direction
0: Consistent with
the set direction
F0.18
Auxiliary 1: Reverse to the set
function setting direction
1
LED Tens: Jog
priority selection
0: Highest
1: Lowest
0: Output lower
limiting frequency
when it is lower
Lower limiting than the lower
F0.19
frequency limiting frequency
functioning 1: Output zero
1
mode
frequency when it is
lower than the
lower limiting
frequency
F0.20
Reserve
Parameter
F0.21 protection 0~9999
1
password
F0.22 UP/DW speed 0.1~50.0Hz
0.1
F0.23
Reserve
F0.24
Reserve
5.0
5.0
10.0
10.0
0000
0
0
5.0