Function Parameter Table 20
5 Function Parameter Table
Parameter Function
Type Code
Name
Setting Range and Minimum Default
Description
unit setting
0: Digital setting
1: External analog
quantity
2: External
F0.00
Frequency input communication
channel 3:Panel
potentiometer
1
3
4: Selection of
external terminal
5:Combined setting
F0.01
Frequency 0.0Hz ~ Upper
digital setting limiting frequency
0.1
0.0
LED Units:
Selection of
running command
channel
0: Keyboard control
1: External terminal
control
2: communication
port
LED Tens:
Running command
mode selection
Selection of 0: Two-line mode 1
running 1: Two-line mode 2
F0.02 command 2: Three-line mode
1
1000
channel and
mode
3: Special mode for
terminal machine
LED Hundreds:
REV prevention
0: REV prevention
void
1: REV prevention
effective
LED Kilobit:
Power-on auto start
0: Power-on auto
start forbidden
1: Power-on auto
start allowed
F0.03
Lower limiting
frequency
0.0Hz ~ [F0.04]
0.1
0.0
F0.04
Upper limiting
frequency
[F0.03] ~ 1000Hz
0.1
50.0
F0.05
Acceleration
time
0.1 ~ 600.0 Sec
0.1
5.0
F0.06
Deceleration
time
0.1 ~ 600.0 Sec
0.1
5.0
0: Straight line
F0.07
Acceleration and acceleration and
deceleration deceleration
characteristic 1: S Curve
parameter acceleration and
1
0
deceleration
Modification
limit
E550 Series Universal Low-Power Inverter
    "