Chapter 4 Detailed Parameter Description
FC300
P087
P088
P089
P090
P091
30
Special
operation
Discharging
starting voltage
of braking
resistor
Anti-overvoltage
response point
Anti-overcurrent
response point
X1 function
choice
User can carry out some special operations by setting
this function. It will automatically reset to 0 after the
operation, with no memory.
Setting range:
0, No operation;
1, Reset to factory value;
2, Memorize user password;
3, Clear user password;
4, Upload parameter;
5, Download parameter;(Notice: download available
only when software versions are the same; user needs
to consider compatibility when copying between
different power and models)
Others: reserved, cannot be set freely.
Setting range:
220V inverter: 350—400V
380V inverter: 650—720V
Setting range:
220V inverter: 350—420V
380V inverter: 650—760V
Setting range: 100—190% x motor rated current
Setting range:
0, No operation
1, Multi-section speed 1(annexed table 1);
2, Multi-section speed 2 (annexed table 1);
3, Multi-section speed 3(annexed table 1);
4, Frequency rise;
5, Frequency decline;
6, Forward jog;
7, Reverse jog;
8, Forward;
9, Reverse;
10, Forward trigger;
11, Reverse trigger;
12, Stop;
13, Free stop;
14, Mandatory stop;
15, Mandatory reverse;
16, Counter zero;
17, Counter input;
18, Program running reset;
19, External fault;
20, External reset;
21, Acceleration & deceleration time choice 1;
(annexed table 2)
22, Acceleration & deceleration time choice 2;
0
360V
or
660V
380V
or
730V
150
8
    "