FC300
Chapter 4 Detailed Parameter Description
P065
Running
command
resource setting
Setting range:
0, Operation panel control
(forward starting, reverse starting, stop);
1, External terminal control
(forward/stop, reverse/stop);
2, External terminal control
(forward/stop, reverse/stop);
3, External terminal control
(forward starting, reverse starting, stop (normally
close));
4, External terminal control
(forward starting, reverse starting, stop(normally
open));
5, Above 0-3 auto-adaptation.
This function is to choose the control method of
inverter starting and stopping. In below explanation,
X1 terminal is assumed to be forward, X2 to be
reverse, X3 to be stop.
When operation panel control (0) is chosen, external
terminal control turns invalid. Forward starting key
RUN, reverse starting key REV, stopping key STOP are
used to control motor starting and stopping.
When external terminal control (1) is chosen, when
X1(forward) switches on COM, forward starting;
switches off, stop. When X2(reverse) switches on COM,
reverse starting; switches off, stop.
When external terminal control (2) is chosen, when
X1(forward) switches on COM, starting; switches off,
stop. When X2(reverse) switches on COM, reverse
starting; switches off, forward.
When external terminal control (3) is chosen, X3(stop)
and COM are connected to stop button normally close
contactor, X1(forward) and COM are connected to
forward button normally open contactor, X2(reverse)
and COM are connected to reverse button normally
open contactor.
When external terminal control (4) is chosen, X3(stop)
and COM are connected to stop button normally open
contactor, X1(forward) and COM are connected to
forward button normally open contactor, X2(reverse)
and COM are connected to reverse button normally
open contactor.
When 0-3 auto-adaptation (5) is chosen, inverter can
work in all conditions 0-3. Notice: X1 and X2 are both
connected to COM, motor reverse rotating is initiated.
Special caution: Under conditions in which human
safety, production loss or equipment damage are
possibly caused, please set this parameter correctly to
avoid accidents.
5
27