Chapter 4 Detailed Parameter Description
FC300
P036
P038
P039
P040
P041
P042
P043
P044
P045
P046
P047
P048
P049
24
Seventh
frequency
First acceleration
time
First
deceleration
time
Second
acceleration
time
Second
deceleration
time
Third
acceleration
time
Third
deceleration
time
Fourth
acceleration
time
Fourth
deceleration
time
Frequency
acceleration &
deceleration
speed control by
keypad
Frequency
acceleration &
deceleration time
interval
Frequency
memory
Power-down
settlement
Setting range:lowest operation frequency-highest
frequency
Setting range:0.1-3000.0S
This parameter is to set the needed time for inverter
to increase output frequency from 0 to highest
frequency.
Setting range:0.1-3000.0S
This parameter is to set the needed time for inverter
to decrease output frequency from highest frequency
to 0.
Setting range:0.1-3000.0S
Setting range:0.1-3000.0S
Setting range:0.1-3000.0S
Setting range:0.1-3000.0S
Setting range:0.1-3000.0S
Setting range: 0.1—3000.0S
Setting range: 0-100.
When the frequency is adjusted by ▲▼keys on
keypad, frequency acceleration speed can be slowed
down by decreasing this parameter value.
Setting range: 1-2000.
When frequency is adjusted by external control
terminal, frequency acceleration speed can be slowed
down by increasing this parameter value.
Setting range:
0,No memory
1, With memory
2,Memory for the latest frequency before starting.
To set whether first frequency (P030) is memorized
after power-off.
Setting range:
0, Reporting undervoltage and locking;
7.0Hz
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
1
0