FC300
Chapter 4 Detailed Parameter Description
CHAPTER 4 DETAILED PARAMETER DESCRIPTION
Parameter
Number
P000
P001
P002
P003
P004
P005
P006
P007
P008
P009
P010
P011
Function
Inverter model
code
identification
MotorRatedcurr
ent
Motor rated
voltage
Motor rated
frequency
Motor no-load
current
Reserved
Reserved
Torque boost
Reserved
Reserved
Reserved
Reserved
Explanation
Setting range:
0, 0.75KW/220V ; 1, 0.75KW/380V ;
2, 1.5KW/220V ; 3,1.5KW/380V;
4, 2.2KW/220V ; 5, 2.2KW/380V ;
6, 3.0KW/220V ; 7, 3.0KW/380V ;
8, 3.7KW/220V ; 9, 3.7KW/380V ;
10, 5.5KW/220V ; 11, 5.5KW/380V ;
12, 7.5KW/220V ; 13, 7.5KW/380V ;
14, 11KW/220V ; 15, 11KW/380V ;
16, 15KW/220V ; 17, 15KW/380V ;
18, 18.5KW/220V ; 19, 18.5KW/380V.
Setting range:20 -110% inverter
current,
depends on the rated current of actual used motor.
When the inverter drives two or more motors, there’s
no motor protection, so please install thermal
protection relay for motors in this case.
Setting range:50-460V
Set in accordance with the rated voltage of the actual
used motor.
Setting range: 20.0-1000.0Hz
Set in accordance with the rated frequency of the
actual used motor.
Setting range: 20%-50%
The ratio of motor no-load current to motor rated
current will influence the slip compensation amount.
Factory
Value
Factory
setting,
only for
reading
Dependi
-ng on
motor
model
220V
(380V)
50.0Hz
40
Setting range: 0-30% (depending on motor model)
This parameter sets the lowest starting voltage of V/f
curve. Setting this parameter properly can improve the
starting torque at low frequency.
Dependi
-ng on
motor
model
21