FC300
Chapter 3 Keypad Operation
J
present count value
d
factory test reservation
3.1.3 Operation Keypad Explanation
If parameters need modification, first you shall enter into the function code which requires
modification, then reset the parameter. Refer to details as below:
Sequence
1
Operation
Explanation
Enter into function setting state, inverter displays present
parameter number, e.g. “P000”.
2
Adjust to the required parameter number, e.g. “P087”.
3
Inverter displays the value of present parameter, e.g.”0”.
4
Adjust to the required value, e.g. “101”.
5
confirmthis operation and save the data.
6
Exit the setting state and back to standby or running state.
Notes:
Press “ESC” and enter into function setting state, if “ESC” is kept been pressing for more
than 3 seconds before being released, inverter will enter into special mode in which it can
only display and modify Non-factory parameters (which were modified from factory
parameters before).
When setting parameters, pressing “ESC”key can exit parameter setting state and back to
standby mode.
17