4.4 Principle of the Input Interface for Switching Value
Figure 4.3-a Input Interface for Switching Value
Servo controller
● The input interface should be externally connected to a power supply of DC12V-24V with a
current equal to and more than 105MA.
● Inverse connection of the positive and negative poles may damage the driver and make it
unable to work normally.
4.5 Principle of the Output Interface for Switching Value
Figure 4.3-b Output Interface for Switching Value
Servo controller
● The maximum output voltage is 25V and the maximum output current is equal to and less than
55MA.
37