Chapter III Wiring
3.1 Notices
The servo driver is a high voltage e heavy current product. Improper connection may cause
damage to personnel and equipment.
PE terminal must be connected to a ground wire and make sure that the ground wire is reliably
grounded.
AC 220V power supply is suitable for this product. Do not connect an AC380V one to the servo
driver.
The U, V and W of the product should be connected with the motor. They are outputs. Do not
connect them with input power supply.
Do not connect the three-phase outputs U, V and W of the product in an incorrect sequence;
because incorrect connection may lead to motor racing, damage to equipment, and overcurrent
burnout to the product.
Tighten all terminals. The materials of all matching wires should be strictly selected according
to power.
Power distribution and touching of the terminals are not allowed when the driver is electrified.
Do not touch the terminals within five (5) minutes after power down.
It is not allowed to touch the motor and cables when the motor is in operation in order to avoid
accidental injuries such as scalding and wrench, etc.
3.2 Wiring Requirements
A three-phase isolation transformer is preferred for power supply.
The required diameters of R, S, T and U, V, W, PE wires should be equal to and more than
1.5mm2.
All power terminals should be cold-pressed ones, firm and reliable.
CN1 and CN2 are high-density signal plugs that need cables with a shielding layer.
The wires for connecting PE terminals should be yellow-green ones with a diameter equal to
and more than 2.5mm2.
3.3 Wiring Methods
A three-phase isolation transformer is preferred for power supply.
16
    "