Shenzhen Reader Technology Co., Ltd
If it is only provided with the single laser, it can show the one-path
parameter.
Prompt
(3) Other Manufacturer Parameters
Machine Type: In most cases, the general engraving machine should be
selected and other types used for specific purposes.
Feeding Mode: it has single-way mode and two-way mode for option. If it is of
single-way feeding, it is unnecessary to check the coordinates. Feeding can be
conducted in the single-way mode; if it is of two-way feeding, the system will
check the maximum and minimum coordinates. The odd sequence means
feeding should be done to one direction and the even sequence means feeding
done to the other direction. The initial direction for the first time can be changed
through setting the directional polarity or modifying the plus and minus values of
the feeding length. This parameter is valid only when the “Z axes function” is
configured to “Drive for Feeding axes”.
Power-Off-Restart Delay: it can be set to be 0~3000ms. After the power-off of
the electricity grid, the power supply of the system will not drop to 0 at once.
There is a delay during this time. The delay value set here should basically
consistent with the actual off-delay value. If the deviation of set value is larger, on
the de-energizing for continuous engraving, either the figure processed for the
second time is not closed with that before the cutoff, or it is coincided with that
too much.
Transmission Mode: generally the “Belt Stepping Type” should be made choice
of. The control algorithm will be changed a little when other types are selected.
Z Axes Function: “Drive for flat” or “Drive for Feeding axes” are optional.
Prompt
After the configuration parameters in the manufacturer parameters, such
as directional polarity, control mode, laser type and laser PWM
frequence, are modified, the system should be reset. Such a
modification can function upon the resetting of the system.
(4) Enable Parameters
Laser 1 Enabled
Laser 2 Enabled
Water Protector 1 Enabled
Water Protector 2 Enabled
Door Opening Protection
Whether to Enable the blower
Prompt
The Enable Parameters are to enable or disable above functions. If the
machine is provided with the parameter for the single laser in the
manufacturer parameters, the display entry of enabling parameter will
39
    "