RDZ01 LFS Manual
PIN12 OUT4
PIN13 OUT5
PIN14 OUT6
PIN15 OUT7
PIN16 OUT8
PIN17 +24V
PIN18 +24V
PIN19 GND
PIN20 GND
O2 controls relay output.
O2 for punching hole
Compressed air relay control
output
Laser head crash alarm
output
Communication
signal
UpSign
Communication
signal
DnSign
External 24V power supply
input
External 24V power supply
input
External 24V reference GND
External 24V reference GND
blow. When finished cutting , stopping
blowing O2
If user has select 1 channel auxiliary gas (set
by LFS controller software), no matter in
manual or automatic mode, the output is
disconnected. If select 2 channels auxiliary
gas, OUT2 ended and OUT5 conduct when in
manual mode, and OUT5 ended In automatic
mode.
If user has select 1 channel auxiliary gas (set
by LFS controller software), no matter in
manual or automatic mode, the output is
disconnected. If select 2 channels auxiliary
gas, OUT2 ended and OUT5 conduct when in
manual mode, and OUT5 ended In automatic
mode.
This signal is connect to DrProc of
RDC633XM.
When the signal is low, RDC633XM will
stop motion and give the alarm information
Communication with RDC633XM
Communication with RDC633XM
Pin
Signal
PIN4 LMT_N
PIN8 LMT_P
Figure2-2 CN1 Interface definition
Definition
Description
Down limit signal input When live focusing, to protect the laser
head from crashing.
Low level is valid
Upper limit signal input When live focusing, to protect the laser
head from crashing.
RuiDa Technology
1B-1,Building 5,Tian'an Nanyou Industry Area,
Dengliang Road,Nanshan District, Shenzhen
Telephone:86- 0755-26066687
E-Mail: support@rd-acs.com 9
Web: www.rd-acs.com
FAX: 86-0755-26982287