User still can selet the “check follow up ” to be “use delay” and the “check follow” to
be “using trigger”.
The first operation should be careful. The following step should be noticed
1) If the drive is servo drive, please set the parameters correctly according to the
operating manual of the servo drive。
2) Then power on the distance controller, go to the “MENU”“Setting”. Configure the
parameters correctly.
3) To check the limit switch is good or not. User can trigger the limit manually. If it work
well , the information of up limit trigger or down limit trigger will be displayed in the
screen. That means the limits are working well.
If the polarity of the limit is wrong, please check and modify the polarity of the limit in
the menu.
Then check the crash alarm is good or not. Just move the laser head or the work piece
to keep they touch each other. If there are crash alarm information displays in the
screen, which means the crash alarm is ok.
4) Press
check the moving direction of the laser headif the direction is not
the desired direction, then modify the “motor polarity”
5) Calibration. If the calibration result is good, then save the data.
    "