Laser Engraving & Cutting Control System Manual
3.4 Technics Process
3.4.1 Setting the Stop Position of the Laser Head
The corresponding icon is on the toolbar. The laser head will move to the point after the data is processed. Click the
button and the mouse cursor will change to a Circle, followed by the appearance of the dialog box below:
There are 4 modes:
Related selectionFirst select part of the graph. Select the Related Selectionoption, and select a relative position of the
graph (i.e. Left up, Right down).
Relative whole graph: Without selecting the Related Selectionoption, select a relative position of the graph (i.e. Left up,
Right down).
Fixed PositionSelect Fixed Posand input the coordinate value to set the Stop Point precisely.
AnywhereMove the mouse to any point and set the Stop Position as you need.
3.4.2 Set Start Point
This is the corresponding icon: on the toolbar. The system will automatically define the start point (usually the crossed
point of two lines) and the direction of cutting process. Select the vector graph. Click this button, move the mouse to the
vector graph, and the mouse will change to a Cross. Click the mouse on any position of the vector graph. The point will be
the start point of cutting. Click on ‘F’ to invert the direction. Here is how it will appear:
22