RDWork Laser Engraving Cutting Software V1.3
4.10.4 Laser Dot Parameters Setting
The time for emitting laser
on one dot during the process.
The higher the value is, the
The interval between the
dots
Dot length, for cutting dash
line
Only dot at center
4.11 Vendor settings
4.11.1 The motor parameters
X Y Z U axis parameters
Dir polarity: Change the direction of polarity can make the motor to the reverse direction.Modify
the goal is to make the shaft to the origin when reset,if reset when the axial direction away from the
origin,explain the polar axis direction set wrong,should be modified.
Limiter polarity: Used to set the limit of high and low level signal model,If moving axis reaches the
limit position ,enter a low level signal to the main board ,the limit should be set to a negative polarity.
Breadth: The longest distance between the axes can walk,according to the actual situation of the
machine.
Home offset: If the shaft can make the hard limit protection,often should set the value of 2~5mm,if
set to 0,then the axes coordinate zero run to minimum,effective,has the potential to limit such trigger
SHENZHEN RUIDA TECHNOLOGY
68
    "