RDWork Laser Engraving Cutting Software V1.3
SN Inc: the interval number can be prescribed sequence number. Example will in turn processing
from 0001 to 9999 serial number, the increment is 1.
If only need to output even or odd number serial number, can set incremental is 2.
Enable reset: when serial number processing to reset the serial number, current SNwill be
automatically reset to start SN.
Example requires repeated processing from 0001 to 9999, serial Numbers, so can be designated 9999
as reset, serial Numbers, when processing the 9999 serial number, text will automatically change to 0001.
Enable prefix ZERO: if not lead to zero, the system will automatically remove the first in the
serial number of zero digital before the zero. Such as the example, serial Numbers, if not the leader's zero
can ABC0001DEF will become ABC1DEF. But it is worth noting that, if we want to output serial number is
ABC1DEF, ABC2DEF until ABC9999DEF, we can't through the will start SN set to 1 to achieve, but
through the cancel Enable prefix ZEROto achieve, this is because set in the specified number from
the start the serial number which one, beginning outside, also specifies the number of significant digits,
such as will begin to serial number set to 1, the change of the serial number order is:
1,2,3,4,5,6,7,8,9,0,1,2,3,4,5... Serial number won't change to 10, because the effective a serial number
had 1.
Enable SN array to the array of way, one-time processing more serial number.
for instance:
0001 0002 0003
0006 0005 0004
0016 0017 0018
after this batch processing serial number,
skip directly to the next group of
0015 0014 0013
0007 0008 0009
0016 0017 0018
Capture
Click menuDraw->Capture
If the computer has been connected to the image device, the dialog box will appear. After it was
selected, you can collect the pictures from the specified device.