RDC6685U(-DFM) Control System manual
during this time. The delay value set here should basically consistent with the actual off-delay
value. If the deviation of set value is larger, on the de-energizing for continuous engraving,
either the figure processed for the second time is not closed with that before the cutoff, or it is
coincided with that too much.
Prompt
After the configuration parameters in the manufacturer parameters, such
as directional polarity, control mode, laser type and laser PWM
frequency, are modified, the system should be reset. Such a modification
can function upon the resetting of the system.
Enable parameters
Door Opening Protection: If this item is enabled, then the door opening protection
must be connected to the controller, or, the machine will not run.
Whether to enable the blower: If using wind out port to control the blower by the
graph layer parameter, this item must be enabled, or, the wind output is a signal for other using.
Y-axis pressing control: When feeding, is it the Y-axis press, YU axis joint synchronous
feeding machine
Double-head auto layout parameters
Head distance N: This is the distance between the two X axis when they all return
to the absolute origin in the double-head auto layout machine.
Enable Double Header: If enable the function of the double-head auto layout
machine.