Laser Enable: When double lasers are used, then each laser can be respectively
enabled or disabled.
Minimum Power
Maximum Power
Laser PWM Frequency
Pre-generation Frequency
Pre-generation pulse scale: When the laser is RF-laser and it’s need to pre-generate
PWM, then set the Pre-generation Frequency and the Pre-generation pulse scale.
Water Protector Enabled: When the water protector is enabled, the mainboard will
detect the input port of water protector. If this port is of low level, it will be deemed normal; if
this port is of high level, the mainboard will forcibly close the laser to suspend the work in
progress and the system will warn. If the water protector is not enabled, the mainboard will not
detect the input port of water protector and so the water protector can be unconnected.
Laser PWM Frequency is used to set the pulse frequency of control signal used by this laser, in
general, glass tube is about 20KHZ, RF laser is about 5KHZ; the maximum/minimum power (%) is
used to set the limit power of this laser, that is to say, during the operation, the maximum power set
by the user can’t be higher than that set here and the minimum power set by the user can’t be less
than that set here, either. When a laser’s power is attenuated, then the laser attenuation quotiety
may be set
(3)Other manufacturer parameters
Machine configuration
Machine Type: Double cantilever(Dual X ) and double beam(Dual Y) models are
optional. For the coordinate system of each model, see the previous section.
Feeding Mode: it has single-way mode and two-way mode for option. If it is of
single-way feeding, it is unnecessary to check the coordinates. Feeding can be conducted in the
single-way mode; if it is of two-way feeding, the system will check the maximum and minimum
coordinates. The odd sequence means feeding should be done to one direction and the even
sequence means feeding done to the other direction. The initial direction for the first time can
be changed through setting the directional polarity or modifying the plus and minus values of
the feeding length.
Power-Off-Restart Delay: it can be set to be 0~3000ms. After the power-off of the
electricity grid, the power supply of the system will not drop to 0 at once. There is a delay