RDC6685U(-DFM) Control System manual
8.5.4 Backup parameters
In the menu interface, select the "Backup Factory Parameters" entry, press the <Enter> button
and then pop up the password input interface. The password input operation refers to Section 8.9. If
the password is input correctly, the system will backup all the current user parameters and factory
parameters. Interface prompt "Backup parameter is successful".
Prompt
After the manufacturer regulates all parameters of the machine well
(including all manufacturer parameters and user parameters), this
function can be used to store the well-regulated parameters to help
users to recover the original parameters (including all manufacturer
parameters and user parameters) through selecting “Recover Para”
when they regulate parameters improperly.
8.5.5 Restore parameters
In the menu interface, select the "Restore Factory Parameters" entry, press the <Enter> button
and then pop up the password input interface. The password input operation refers to Section 8.9. If
the password is input correctly, the system will restore all the current user parameters and factory
parameters with the factory parameters set before. Interface prompt "recovery parameter is
successful".
8.5.6 Max/Min Power Setting
Push the < Power> key when the screen is on the main interface, it will show as below:
Figure
8.3
SHENZHEN RUIDA TECHNOLOGY
44