RDC6685U(-DFM) Control System manual
it will move to the opposite direction of machine origin, which means the polarity of directional signal
for this axle is not correct. In such a case, the connection between this axle and the motor driver can
be broken first (otherwise the mainboard can not be detected to the spacing so as to lead to the
collision of this axle), and then such a polarity can be corrected after this axle is reset completely.
Upon the correction, the reset key can be pressed against to reset the mainboard.
And, the Pulse signal can be falling edge valid or rising edge valid. The default setting is falling
edge valid.
4.11 Laser Power Control Interface L1-L4
This control system has four independent and adjustable digital laser power control interfaces.
The function for each laser show as below:
Laser
Symbols Definitions
channel
1
L1
The first laser control interface corresponding to the main
coordinate system (X1 /Y1)
2
L2
The second laser control interface corresponding to the main
coordinate system (X1 /Y1)
3
L3
The first laser control interface corresponding to the second
coordinate system (X2 /Y2)
4
L4
The second laser control interface corresponding to the second
coordinate system (X2 /Y2)
Signals of the four interfaces are similar and the first digital interface (L1) is hereby exampled:
Pin
Symbols Definitions
1
GND
Power ground (output)
2
L-ON1
Laser-enabled control interface
1. When the laser is the RF laser, this pin will not be used;
2. When the laser is a glass tube, if the used laser is outputted in
the low-level form, this pin will be connected with the laser power
enable end and used to control the ON/Off of laser.
3
LPWM1
Power control interface of laser/laser tube
1. When the laser is the RF laser, this pin will be connected with
the laser RF-PWM end;
2. When the laser is a glass tube, this pin will be connected with
the laser power PWM end and used to control the power of the
laser.
4
WP1
The input port of water protector for the first laser power source.
When the water protector 1 is enabled, the mainboard will detect
the input port of water protector 1. If this port is of low level, it will
be deemed normal; if this port is of high level, the mainboard will
SHENZHEN RUIDA TECHNOLOGY
24