User’s Manual of RDC6442G(U)-DFM-RD Control System
set on the keyboard when the system is idle (The lasering power on the 4-corner dotting
means the well-set maximum power).
Go scale Blank: It means whether to extend a certain length outside the actual
frame of the figure on the preview/cutting of frame.
Prompt
If the frame crosses the border, the interface will prompt it. If the
Enter key is pressed at this time, the system will cut the border at
the maximum/minimum coordinates first, and then border the
figure. This bordering can be given up.
(5)Other user parameters
Array Mode: Two-way array or one-way array can be selected. Two-way array
means the to-and-fro cutting of array in sequence; one-way array means the cutting of
array from one direction to another. On selecting one-way array, the elements of each
array are the same in action mode and completely uniform in action fluency, which takes
a little more time than two-way array. Two-way array is the default option.
Back Position: The origin (the relative origin) and the machine’s absolute origin
can be selected. This parameter decides the parking position of laser head after each
work.
Focus Setting: it means the distance from the focal point of laser head lens to
Z-axle origin. When there is no automatic focusing function, this parameter becomes
invalid.
Backlash X: The X axes’ backlash, accurate to 1um.
Backlash Y: The Y axes’ backlash, accurate to 1um.
SHENZHEN RUIDA TECHNOLOGY
52