Similarity: The similarity between the Mark point in the visual imaging picture and the set Mark point. This
value will directly affect the matching identification result.
Distance offset: The maximum distance of relative position deviation between the Mark points recognized
by the system.
Angle deviation: The allowable angle deviation when matching.
Cancel deviation error report: When multiple points match Mark points, the system recognizes that the
actual distance between the Mark point and the preset position deviation is greater than the distance deviation
and will prompt an error. If Cancel Deviation Alarm is checked, no error will be prompted.
Differentiation/Contrast: It is valid when the right angle module template is selected.
Matching test:
The current template is matched with the target image in the current field of view of the camera, and the
test result will be returned in the result interface.
Advance:
Enter the advance options to set the template matching parameters.
Webwww.rd-acs.com | TEL/FAX0755-26066687/26982287 84