Key
parameters
Reset
parameters
duration when the primitive starts to be processed. The first
pulse suppression is to prevent over burning at the start
processing position.
Duration of first
pulse
Set the duration of power suppression at the beginning of the
processing position of the primitive.
Manual fast X
Refers to the speed of manually moving the X axis when [Fast
Speed].
Manual slow X
Refers to the speed of manually moving the X axis when [Slow
Speed].
Manual fast Y
Refers to the speed of manually moving the Y axis when [Fast
Speed].
Manual slow Y
Refers to the speed of manually moving the Y axis when [Slow
Speed].
。
Manual fast Z
Refers to the speed of manually moving the Z axis when [Fast
Speed].
Manual slow Z
Refers to the speed of manually moving the Z axis when [Slow
Speed].
Manual fast U
Refers to the speed of manually moving the U axis when [Fast
Speed].
Manual slow U
Refers to the speed of manually moving the U axis when [Slow
Speed].
X axis reset speed
Y axis reset speed
Z axis reset speed
U axis reset speed
X axis power-on
reset enable
Speed when X axis is reset
Speed when Y axis is reset
Speed when Z axis is reset
Speed when U axis is reset
If the X axis power-on reset is enabled, the X axis will be
automatically reset when the machine is turned on, otherwise it
will not be automatically reset.
Y axis power-on
reset enable
If the Y axis power-on reset is enabled, the Y axis will be
automatically reset when the machine is turned on, otherwise it
will not be automatically reset.
Z axis power-on If the Z axis power-on reset is enabled, the Z axis will be
reset enable