3.4 Parameter description
3.4.1 Vendor parameters
Click the button
from the CNC to open the vendor parameter setting interface, the axis parameters,
machine configuration parameters, and clear the control card information can be set here.
X, Y, Z, U Axis
Motion polarity
Limit polarity
Figure: Axis parameters
Modifying the direction polarity can make the motor move in the
opposite direction. The goal of the modification is to make the
axis move in the direction of the origin when resetting. If the axis
moves away from the origin when resetting, it means that the
axis direction polarity setting is wrong and should be modified.
It is used to set the high and low voltage mode of the limit signal.
When the motion axis reaches the limit position and inputs a
low-voltage signal to the mainboard, the limit polarity should be
Webwww.rd-acs.com | TEL/FAX0755-26066687/26982287 47