Add lead wire
Figure: Add lead wire interface
Select to add the lead-in wires or lead-out wires, as well as the length and angle of the lead wire.
automatically set the inner and outer cutting properties of the graphics and automatically detect the validity of
the lead wires as needed.
Auto searching an appropriated angle is to automatically calculate the angle of the added lead wire
according to the graphic characteristics (from the tangent direction or vertical direction).
To check the lead-in and lead-out, you can set the safe distance of lead wires, and modify the qualified lead
wires (check the inference among the lead wires and the graph itself and other graphs)
Modify lead-in lead-out wires: Enter the modification status, use the left mouse key to drag the end point
of the lead wires to the desired position. (Status operations press the ESC key to exit)
Detect lead-in lead-out wires: set the lead wires safe interval in the pop-up window, if the lead wires
intersect the original primitives, it will be shortened automatically. The safe interval of the lead wires is
generally set to be relatively small, otherwise it will easily cause the failure of lead wires addition.
Modify starting point:
Click to modify the starting point icon
to enter the state of modifying starting point. Click the
mouse in the drawing interface. If the first click is outside the graph, and the second click is on the graph, add a
lead wire between the first click position and the second click position, and modify the starting point to the
second click position. If you click on the graph for the first time, the starting point is directly modified to this
position (the starting point of the non-closed graph cannot be modified). (Status operations press the ESC key to
exit)
Positioning setting:
Set the graphic reference point (the point marked by the green square) as a reference for various motions of
the graph (it is used when the floating coordinate system and the workpiece coordinate system are processing).
User can directly specify the 9 relative positions of the selected graphics as the reference points, or you can use
Webwww.rd-acs.com | TEL/FAX0755-26066687/26982287 31
202-203, B-Block,Technology Building, 1057 Nanhai Avenue,Nanshan District,, SHENZHEN, CHINA