RDC644XG Controller User Manual
set too high, it may cause the jarring of track, so comprehensive consideration should be given to the
setting.
Turning Speed: the turning speed at closed-angle corner, the lowest speed in the whole cutting process.
Turning Acceleration: the acceleration speed at the closed-angle corner when cutting. If the two speeds
are set too large, vibration will be happened when turning; if set too low, it will influence the cutting
speed.
Cutting Acceleration: it means the highest acceleration value in the whole cutting process.
Acceleration Mode: it is divided into T acceleration and S acceleration. T accelerate will quicken the
whole cutting process, but it will result in that its cutting effect is inferior to that of S acceleration.
One Key Setting: This is one recommended cutting parameters settings button; it is not a parameter,
there are several groups of parameters under this button, which is convenient for selection.
(2) Scanning Parameters (Only affect scanning mode)
X- axis Starting Speed
Y- axis Starting Speed
X- axis Acceleration
Y- axis Acceleration
The above four parameters are used to set the starting speed and acceleration of two axles when scanning.
The higher the two speeds are, the quicker the scanning is.
Scanning Line-feed Speed: this parameter is specially used to control the highest speed at which that the
previous line vertically moves to the next line in the scanning mode. If the space between lines is larger
during the scanning or if the distance of each block is larger during the scanning and deblocking of figure,
it is necessary to position each line or block accurately. In such a case the speed of scanning line-feed can
be set as a lower value.
Scanning Mode: it is divided into general mode and special mode for option. If special mode is used, the
laser power should be increased. The smaller the speckle percentage is, the more the laser power reduces.
The laser power to set should be larger in order to reach the same scanning depth. The purpose to select
the special mode is to make the laser light at high power and short time. On the depth scanning the effect
that the bottom is flatter is obtained, but it should be noticeable that if the speckle adjustment is not
appropriate, it can achieve this goal. If the high power remains short, the lighting mode will influence the
life of the laser. The system will default the selection of general mode.
Spot Size: When the general mode is selected as the scanning mode, this parameter will become
48 / 51