RDC644XG Controller User Manual
Power-Off-Restart Delay: it can be set to be 0~3000ms. After the electricity grid power-off, the power
supply of the system will be not dropped to 0V at once. There is a delay during the time. The delay value
set here should basically consistent with the actual off-delay value. If the deviation of set value is larger,
on the de-energizing for continuous engraving, either the figure processed for the second time is not
closed with that before the cutoff, or it is coincided with that too much.
Transmission Mode: generally choose “Belt Stepping Type”, the control algorithm will be changed a
little when other types are selected.
Prompt
After modified the configuration parameters in the manufacturer parameters,
such as directional polarity, control mode, laser type and laser PWM
frequency, the system should be reset. Such a modification can function upon
the resetting of the system.
(4) Enable Parameters
Cover Opening Protection: If enabled this item, the controller must connect the protection wiring,
otherwise, the machine will not work.
Enable the blower: if use Wind signal of output port to control the blower switch as layers, you must
enable this item, otherwise, the Wind signal outputs other signal.
Prompt
The Enable Parameters are to enable or disable the above functions. If the
machine is provided with the parameters for the single-laser in the
manufacturer parameters, the display entry of enabling parameters will be
changed accordingly.
9.2 User Parameters
(1) Cutting Parameters (Only affect cutting methods)
Idle Move Speed: this parameter decides the highest speed of all non-lighting lines for the machine in the
movement process.
Idle Move Acceleration: it means the highest acceleration of all non-lighting lines. Idle stroke speed and
idle stroke acceleration can be set higher to reduce the working time of the whole figure, but if they are
47 / 51
© 2016 Ruida Technology. All Rights Reserved.
    "