RDC644XG Controller User Manual
Maximum Power
Minimum Power
Laser PWM Frequency
Pre-burning Frequency
Pre-burning Pulse width: when the laser is RF laser and need pre-burning pulse, you can configure the
features of pre-burning pulse by pre-burning frequency and pre-burning pulse width.
Water protection enables: When the water protection enabled, the controller must connect the wiring,
otherwise the machine will not emit laser. If disable, no need to connect the water protect wiring,
controller will not test.
Laser PWM Frequency is used to set the pulse frequency of control signal used by the laser, in general,
glass tube is about 20KHZ, RF laser is about 5KHZ; the maximum/minimum power (%) is used to set the
limit power of the laser, that is to say, during the operation, the maximum power set by the user which
can’t be higher than the maximum power and the minimum power set by the user which no less than the
minimum power. When the laser power is attenuated after using for a time, then can set the laser power
by the attenuation quotiety.
If it is only provided with the single laser, it will show the one-path parameter.
Prompt
(3) Other Manufacturer Parameters
Machine Configuration
Machine Type: In most cases, the general engraving machine should be selected and other types used for
specific purposes.
Feeding Mode: single-way mode and two-way mode for optional. If it is single-way feeding, it is
unnecessary to check the coordinates, feeding can be conducted in the single-way mode; if it is two-way
feeding, the system will check the maximum and minimum coordinates. The odd sequence means feeding
should be done to one direction and the even sequence means feeding done to the other direction. The
initial direction for the first time can be changed through setting the directional polarity or modifying the
plus and minus values of the feeding length. This parameter is valid only when the “Z axes function” is
configured to “Drive for Feeding axes”.