RDC644XG Controller User Manual
independently be prohibited and enabled.
Set Origin 1/2/3/4: after the multiple- origin logic is enabled, you can stop the cursor at “Set as
Origin 1/2/3/4”. Press the “Enter” key on the keyboard and the system will take the coordinate
figures of current X/Y axis as the corresponding ones to the origin 1/2/3/4.
Next Origin: there are such five digits as 0~4 for option, which are the origins to be used for
the next figure. Origin 0 means the origin set by the “Origin” key on the panel in the single-
origin logic. 1~4 means the serial number of the origins in the multiple- origin logic. Next
origin can be modified to any one of origin 1~4, so as to control the start location of next work
(the premise is that the origin is enabled), but it can’t be modified to origin 0.
Prompt
Once the multiple- origin logic is selected and if the serial number of the next
origin is 1 and four origins are enabled, when the memory file function is started
or the processing file is uploaded into the PC and this file selects “Take the
Original Origin as current Origin”, the work started for each time will use
different origins. The rotation order of origin is 1->2->3->4->1->2…….
8.3.7 Set Factory Para
After the “Set Fact Para” is selected and the Enter key pressed, the interface will show the specific
password to be entered when set as default parameter.
Figure 8.3-6
Push “X+/-” keys and “Y+/-” keys to select the characters, and push the “Enter” key to valid the
characters, when finishing enter the password ,that is to say, the six characters, if the password is error, it
prompts there is some error, or, all parameters are stored.