CHAPTER 14 PC LOADER
14.6.2 Historical Trace
The motion waveform of the servomotor is drawn.
Data of 500 points is acquired.
Enter trigger settings to acquire the local waveform
to be observed.
[Historical trace screen]
Relationship between sampling time and
tracing time
Sampling time [ms]
Tracing time [s]
0.125
0.250
0.500
1
2
5
10
20
50
100
200
0.0625
0.125
0.25
0.5
1
2.5
5
10
25
50
100
You can show the interval between two points, overlap waveforms, perform FFT analysis, re-load the
waveform, copy the screen, show parameter data of the acquired waveform, save the waveform (in a
CSV file), or do other things.
14