CHAPTER 14 PC LOADER
14.6 Detail Description of Function
14.6.1 Real-Time Trace
Servomotor motion waveforms are drawn. Data of
about 60,000 points can be acquired continuously.
The trace is automatically terminated when the
limit of 60,000 points is exceeded.
Select the desired waveform and press the
"START/STOP" button to acquire the waveform.
[Example of real time trace screen]
Relationship between sampling time and tracing
time
Sampling time [ms]
Tracing time [s]
1
60
2
120
5
300
10
600
20
1200
50
3000
100
6000
200
12000
You can show the interval between two points, overlap waveforms, perform FFT analysis, copy the
screen, show parameter data of the acquired waveform, save the waveform (in a CSV file), or do other
things.
Tabs
Buttons
For detail description of each tab and button,
refer to the Help of PC Loader.
14