CHAPTER 14 PC LOADER
14.3 Communications Setting
Two methods are available to connect the servo amplifier to a PC.
The communications setting detail varies depending on the connection method. See the following
description and set the communications appropriately.
1) When using the RS-232C/485 converter (NW0H-CNV)
Wiring outline
RS-232C/485 converter
(NW0H-CNV)
CAT5 cable
(commercial item)
USB/serial cable
(commercial item)
Setting method
(1) Select "Comm. Setup" from
Wizard Menu.
PC Loader
(2) Select "It communicates directly with the
amplifier(COM)." in the Connection method
item, and then click the OK button.
14
Notes
Set the same value between PA2_73 (communications baud rate) on the amplifier side and the
communications baud rate as a communications condition.
No. Parameter name
Setting range
Default value Change
PA2_73 Communications 0・・・ 38400 [bps]1・・・ 19200 [bps]
baud rate
2・・・ 9600 [bps]3・・・115200 [bps]
0
Power
14-6 Communications Setting