CHAPTER 13 RS-485 COMMUNICATIONS
13
Alarm history read
CMND
DATA
(n)
50h
Sent from host controller
Memory type
Address (L)
Address (M)
Address (H)
Number of loaded
bytes (L)
Number of loaded
bytes (H)
7
0
02h
Quantity (01 to 02h)
Starting No. (01 to 20h)
11h
(Quantity × 32) + 2
Designate addresses (L) and (M) in a BCD.
<Alarm-related data>
Code
00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
10h
11h
21h
22h
23h
24h
25h
26h
27h
28h
29h
2Ah
2Bh
2Ch
Symbol
-
oc1
oc2
oS
-
Hu
Et 1
Et 2
ct
dE
Fb
cE
tH
Ec
ct E
oL1
oL2
r H4
LuP
r H1
r H2
r H3
oF
AH
EH
dL1
dL2
dL3
AF
IE
Name
(No 名de称tection)
Overcurrent 1
Overcurrent 2
Overspeed
-
Overvoltage
Encoder Trouble 1
Encoder Trouble 2
Circuit Trouble
Memory Error
FFuusseeBBrlookwen
Motor Combination Error
Breaking Transistor Overheat
Encoder Communication Error
CONT(Control signal)Error
Overload 1
Overload 2
Inrush Current Suppression Circuit Trouble
Main Power Undervoltage
Internal Breaking Resistor Overheat
External Breaking Resistor Overheat
Breaking Transistor Error
Deviation Overflow
Amplifier Overheat
Encoder Overheat
Absolute Data Lost 1
Absolute Data Lost 2
Absolute Data Lost 3
Multi-turn Data Over Flow
Initial Error
Sent from servo amplifier
Memory type
Address (L)
Address (M)
Address (H)
Number of loaded
bytes (L)
Number of loaded
bytes (H)
STR1
STR2
7
0
02h
Quantity (01 to 10h)
No. (01 to 20h)
11h
(Quantity × 32) + 2
Status data
Alarm code
(L)
(H)
Total time-main
(L)
power supply
(H)
Cumulative excitation
(L)
time of control circuit
(H)
Motor running
(L)
time
(H)
Alarm history of
Feedback speed
(L)
(H)
designated
number
Feedback speed
(L)
(5ms before)
(H)
(32 bytes)
Command
(L)
speed
(H)
Command
(L)
torque
(H)
Motor current
(L)
(H)
Effective torque
(L)
(H)
DC link voltage
(L)
(H)
EC error count
(L)
(H)
Command position
(L)
(high order word)
(H)
Command position
(L)
(low order word)
(H)
Sequence mode
(L)
(H)
Alarm history of
designated
number by
designated
quantity (32 bytes)
Dummy
00h
00h
13-52 PC Loader Communications