CHAPTER 13 RS-485 COMMUNICATIONS
13.2.12 Communications
Reading multi-monitor data
The designated multi-monitor data is read in hexadecimals.
The number of monitor data read at a time is four.
CMND 50h
DATA
(n)
Code
00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
10h
11h
12h
13h
14h
Sent from host controller
7
0
Memory type
01h
Address (L)
Address (M)
Address (H)
Number of loaded
bytes
Dummy
00h
00h
04h
16h
00h
Data 1 designation
BCD (See below.)
Data 2 designation
BCD (See below.)
Data 3 designation
BCD (See below.)
Data 4 designation
BCD (See below.)
Monitor name
No designation
Feedback speed
Command speed
Command torque
Peak torque
Motor current
Effective torque
Feedback position
Command position
Position deviation
Command Pulse frequency
Feedback cumulative pulse
Command cumulative pulse
LS-Z pulse
Load inertia ratio
Code
15h
16h
17h
18h
19h
20h
21h
22h
23h
24h
25h
26h
Monitor name
DC link voltage (max.)
DC link voltage (min.)
VREF input voltage
TREF input voltage
OL thermal value
BReragkeinnegrarteivseisretosirsttohrethrmeramlavl avaluluee
Power
Motor temperature
Overshoot unit amount
Settling time
Resonance frequency 1
Resonance frequency 2
Sent from servo amplifier
7
0
Memory type
01h
Address (L)
Address (M)
Address (H)
Number of loaded
bytes
Dummy
00h
00h
04h
Same as request
00h
STR1
STR2
Data 1 designation
Status data
Sam0e0aHs request
Data 2 designation
Same as request
Data 3 designation
Data 4 designation
Same as request
Same as request
LL
Monitor data 1
LH
HL
HH
LL
Monitor data 2
LH
HL
HH
LL
Monitor data 3
LH
HL
HH
Monitor data 4
For manufacturer
LL
LH
HL
HH
Reserved
For details of monitor data, refer to the next page.
13
PC Loader Communications 13-47