CHAPTER 13 RS-485 COMMUNICATIONS
13
13.2.6 Command List
Command list
No.
Function
Monitor relations
01 Data read with multiple monitors
Sequence monitor relations
02 Sequence mode read
03 System status read
04 Alarm at present read
05 Alarm history read
06 Sequence I/O signal read
Parameter editing relations
07 PA1 parameter read
08 PA1 parameter write
09 PA2 parameter read
10 PA2 parameter write
11 PA3 parameter read
12 PA3 parameter write
Operation command relations
13 Alarm reset
14 Alarm history Initialization
CMND
50h
50h
50h
51h
50h
51h
50h
51h
51h
メMeモmoリry種typ別e
Data section
Address (L)
Address (M)
Address (H)
01h
00h
00h
04h
01h
04h
02h
00h
00h
10h
11h
12h
00h
21h
Quantity
(1 to 15)
No.
(1 to 99)
01h
00h
22h
Quantity
(1 to 15)
No.
(1 to 99)
01h
00h
23h
Quantity
(1 to 15)
No.
(1 to 99)
01h
01h
17h
08h
00h
01h
23h
13.2.7 Command Transmission Specifications
The message exchanged between the host and amplifier is categorized into the following two types:
Transmission message: Message sent from host to amplifier
Response message: Message sent from amplifier to host
Communication is not made between amplifiers.
13-42 PC Loader Communications