CHAPTER 13 RS-485 COMMUNICATIONS
13.2.3 Transmission Protocol
13
Transmission format
Order
(1)
(2)
(3)
(4)
(5)
Description
(Hexadecimal value)
Start code
Count of No. of pieces of data
Fixed value used by system
Process status
Connection method
(6) Amplifier station No.
(7)
Fixed value used by
system
(8) CMND
(9) MODE
(10) End data
(11) Sequence No.
(12) Data section count
(13) Fixed value used by system
(14) Data section
(15) BCC
Transmission command
(From host to amplifier)
5A
No. of pieces of data
00
FF
7A
00: Fixed
Reception command
(From amplifier to host)
5A
No. of pieces of data
00
00
7A
00: Fixed
Station number of target
amplifier
Amplifier station No.
11
11
00
00
FF
FF
FF
FF
FF
FF
FF
FF
As per command As per command
00
00
00
00
01
01
No. of pieces of data of No. of pieces of data of
data section
data section
00
00
Memory type
Address (L)
Memory type
Address (L)
Address (M)
Address (M)
Address (H)
Address (H)
No. of loaded or written
bytes
No. of loaded or written
bytes
00
00
STR1
As per command
STR2
As per command
Calculated BCC
Calculated BCC
*1: The range of calculation of the BCC is from (2) to (14).
*2: The range of counting of the number of data pieces is from (4) to (15).
13-40 PC Loader Communications