CHAPTER 13 RS-485 COMMUNICATIONS
13
(4) Definition of amplifier’s timings
Timings on the amplifier side are defined as follows:
FC
Information field
T1
Other
115200 bps1.7 ms
than
-
38400 bps5 ms
10h
19200 bps10 ms
10h Other than below 9600 bps10 ms
Specify that n sets
of parameters or
Within (n+2)×10 ms
positioning data are
written in
T2
115200 bps1.7 ms
38400 bps5 ms
19200 bps10 ms
9600 bps10 ms
Recommended
T3
timeout setting
Same
as T1
100 ms
250 ms
Response time
It is able to specify a response time of the amplifier (T1) by PA2_94 (response time).
However, actual response time becomes {time for 3 characters + time for executing processing} (T0)
or longer.
* Although T0 varies depending on communications baud rate, FC, and so on, the shortest time is 2.5
ms for 38,400 bps.
If any time longer than T0 is specified, the amplifier responses after waiting for the specified time.
Master
Query
Amplifier
T0
PA2-94 < T0
PA2-94 > T0
PA2-94
Response
PA2-94
Response
After the master has sent a query, if it takes a long time until the master switches into the receiving state,
set PA2_94 (response time) as needed because responses from the amplifiers might not be received
correctly.
3. Error processing
Errors are classified into the following:
(a) Physical/character-level errors
(b) Protocol level error (1)
(c) Protocol level error (2)
: Parity error, framing error, and so on
: CRC error
: Incorrect FC/address/data
13-34 Modbus RTU Communications